Home > Products > Effluent decontamination systems (EDS) > Industrial effluent decontamination systems > ULTIMATE PLUS – Industrial effluent decontamination system

ULTIMATE PLUS - Industrial effluent decontamination system

High-capacity, modular continuous thermal biowaste treatment with integrated energy recovery.

ULTIMATE PLUS is a modular, steam-heated Effluent Decontamination System (EDS) designed for the continuous thermal treatment of biologically contaminated liquid waste in pharmaceutical, biotechnology, and biomanufacturing facilities. With a treatment capacity of up to 50,700 gal/day (192,000 L/day), based on 16 operating hours, ULTIMATE PLUS combines continuous thermal processing, integrated heat recovery, and automated process control in a modular industrial system.

Its modular architecture includes a main treatment skid with a capacity of 13.2 gpm (3,000 L/h) and up to three additional EXT3000 modules. This configuration allows ACTINI to provide treatment capacities from 13.2 to 52.8 gpm (3,000 to 12,000 L/h), depending on project requirements. Designed for aqueous, water-like biological effluents, ULTIMATE PLUS offers controlled thermal treatment, efficient energy recovery, and configurable capacity for industrial facilities.

Key specifications:

  • Capacity: Up to 50,700 gal/day (192,000 L/day), based on 16 operating hours
  • Technology: Continuous thermal EDS
  • Heating: Steam
  • Flow rate: 13.2 – 52.8 gpm (3,000 – 12,000 L/h)
  • Treatment: 176 – 275°F (80 – 135°C), with a 1-minute holding time; optional 2-minute configuration
  • Thermal lethality: F₀ 25 standard; F₀ 50 optional
  • Effluent compatibility: Aqueous, water-like biological liquid waste
  • Configuration: Main treatment skid with up to three extension modules
  • Energy recovery: Integrated, no chilled water required
industrial decontamination unit ULTIMATE PLUS

Why choose ULTIMATE PLUS for industrial biowaste treatment?

ULTIMATE PLUS provides automated continuous thermal decontamination for industrial facilities requiring high treatment capacities and a modular equipment configuration.

Modular treatment capacity

ULTIMATE PLUS combines a main treatment skid with up to three additional EXT3000 modules. ACTINI offers four capacity configurations to match different industrial waste generation volumes.

High-capacity continuous treatment

ULTIMATE PLUS processes biological liquid waste through continuous thermal treatment circuits, supporting flow rates up to 52.8 gpm (12,000 L/h) in the maximum configuration.

Integrated energy recovery

ULTIMATE PLUS recovers thermal energy within the treatment process. Its integrated energy recovery system helps reduce utility consumption and eliminates the need for chilled water.

Automated process control

ULTIMATE PLUS automatically controls and monitors thermal treatment parameters, supporting repeatable operating conditions and coordinated operation of the selected modules.

Configurable industrial integration

ACTINI offers optional redundant pumping and modular equipment arrangements to address specific operational requirements, facility layouts, and project constraints.

ULTIMATE PLUS technical specifications & benefits

Parameter

Specification

Benefits

Equipment ULTIMATE PLUS Modular industrial system for high-capacity biological liquid waste treatment.
Application Industrial liquid biowaste decontamination Supports biological effluent treatment in pharmaceutical and biotechnology facilities.
Technology Continuous thermal treatment Processes flowing biological liquid waste without successive batch cycles.
Heating method Steam Provides thermal energy for controlled continuous treatment.
Maximum daily capacity 50,700 gal/day (192,000 L/day) Supports industrial facilities generating high daily volumes of aqueous biowaste.
Capacity basis 16 operating hours/day Provides a defined reference for preliminary system sizing.
Treatment flow rate 13.2 - 52.8 gpm (3,000 - 12,000 L/h) Offers four capacity configurations for different industrial requirements.
Main treatment skid 13.2 gpm (3,000 L/h) Provides the initial modular treatment capacity.
Extension modules Up to three EXT3000 modules, each rated at 13.2 gpm (3,000 L/h) Allows additional treatment capacity through modular equipment configurations.
Effluent characteristics Aqueous / water-like Designed for suitable water-based biological liquid waste.
Treatment temperature 176 - 275°F (80 - 135°C) Offers a configurable thermal treatment temperature range.
Standard holding time 1 minute Provides a defined thermal exposure period during continuous treatment.
Optional holding time 2 minutes Supports applications requiring a longer thermal holding period.
F₀ - standard configuration 25 Establishes the documented standard thermal lethality target.
F₀ - optional configuration 50 Provides an additional treatment configuration for higher thermal lethality requirements.
Energy recovery Integrated Recovers thermal energy within the continuous treatment process.
Cooling requirements No chilled water required Simplifies facility cooling utility requirements.
Control and monitoring Automated process control Supports coordinated operation and monitoring of the treatment system.
Pump redundancy Optional Provides additional pumping configurations for project-specific operational requirements.
Main skid dimensions (L × W × H) 67 × 98 × 93 in (1,700 × 2,480 × 2,350 mm) Provides dimensions for preliminary equipment layout planning.
Extension module dimensions 37 × 100 × 93 in (940 × 2,530 × 2,350 mm) Helps evaluate the additional installation space required for each module.

Maximum daily capacity depends on the selected configuration, operating hours, thermal treatment parameters, and available utilities. ACTINI confirms the appropriate capacity and installation requirements during project engineering.

How does the ULTIMATE PLUS effluent decontamination system work?

ULTIMATE PLUS uses continuous thermal treatment with steam heating, integrated energy recovery, and a modular processing architecture to decontaminate biological liquid waste.

ACTINI evaluates treatment performance, hydraulic capacity, effluent characteristics, utility requirements, and discharge conditions during project engineering.

1. Biological liquid waste supply

ULTIMATE PLUS receives aqueous biological liquid waste from the facility’s collection and storage system.

The equipment establishes the controlled flow required for continuous operation according to the selected modular configuration.

2. Heat recovery and steam heating

Incoming liquid waste passes through the thermal treatment process.

ULTIMATE PLUS recovers available thermal energy and uses steam heating to bring the effluent to the required treatment temperature.

3. Controlled continuous thermal treatment

The system maintains the selected treatment temperature and holding time as the effluent flows through the treatment circuit.

ULTIMATE PLUS supports temperatures from 176°F to 275°F (80°C to 135°C), with a standard 1-minute holding time and an optional 2-minute configuration.

Automated process control monitors the operating conditions across the selected treatment configuration.

4. Energy recovery, cooling and discharge

Following thermal treatment, ULTIMATE PLUS recovers thermal energy and cools the treated effluent before discharge.

The integrated heat recovery design eliminates the need for chilled water.

Four modular treatment capacities

Configuration

Treatment flow rate

Maximum daily capacity

Main skid 13.2 gpm (3,000 L/h) 12,700 gal/day (48,000 L/day)
Main skid + 1 EXT3000 26.4 gpm (6,000 L/h) 25,400 gal/day (96,000 L/day)
Main skid + 2 EXT3000 39.6 gpm (9,000 L/h) 38,000 gal/day (144,000 L/day)
Main skid + 3 EXT3000 52.8 gpm (12,000 L/h) 50,700 gal/day (192,000 L/day)

ACTINI offers four configurations to match different industrial biowaste treatment requirements.

Daily capacities are based on 16 operating hours per day. Actual performance depends on the selected treatment parameters and operating conditions.

Tecnical schema

ULTIMATE PLUS models and available configurations

Programme de traitement

Main treatment skid

The main skid provides a continuous treatment capacity of 13.2 gpm (3,000 L/h) and forms the basis of the ULTIMATE PLUS modular architecture.

Ajout - scalable - cuve

EXT3000 extension modules

Each EXT3000 module adds a nominal treatment capacity of 13.2 gpm (3,000 L/h). ACTINI can configure the system with up to three additional modules. The modular design allows customers to select a treatment capacity suited to their project. Future additions to an existing installation require an engineering review of utilities, controls, hydraulic connections, and available space.

ISO - environment

Integrated energy recovery

ULTIMATE PLUS incorporates thermal energy recovery into the treatment process, reducing cooling utility requirements and eliminating the need for chilled water.

icone pompe

Optional redundant pumps

ACTINI offers redundant pumping configurations for projects with specific availability or operational continuity requirements.

température icone

Optional extended thermal treatment

ULTIMATE PLUS offers an optional 2-minute holding configuration and an F₀ 50 treatment option. ACTINI evaluates the impact of these treatment requirements on the system's hydraulic capacity and operating conditions.

Typical ULTIMATE PLUS applications

ULTIMATE PLUS is designed for pharmaceutical, biotechnology, and industrial facilities requiring high-capacity continuous thermal treatment of aqueous biological liquid waste.

Potential applications include:

  • Large pharmaceutical and biopharmaceutical manufacturing facilities
  • Biotechnology production and biomanufacturing facilities
  • Vaccine development and manufacturing facilities
  • Industrial bioprocessing facilities generating high volumes of biological effluent
  • Facilities planning modular treatment capacity for production expansion
  • Industrial sites upgrading existing continuous effluent decontamination systems

ACTINI USA evaluates daily waste volume, peak flow, effluent composition, biological treatment objectives, available utilities, and facility integration constraints to confirm equipment suitability.

industrial decontamination unit ULTIMATE PLUS
Tecnical schema

Need a high-capacity modular industrial EDS?

Whether you’re designing a new biopharmaceutical manufacturing facility, expanding production capacity, or upgrading an existing biological liquid waste treatment system, ACTINI USA helps you evaluate ULTIMATE PLUS for your application.

Our engineering team supports process evaluation, modular capacity selection, utility integration, system engineering, commissioning, and qualification activities according to your project requirements.

Frequently asked questions about ULTIMATE PLUS (FAQ)

What is the maximum treatment capacity of ULTIMATE PLUS?

ULTIMATE PLUS treats up to 50,700 gal/day (192,000 L/day) of aqueous biological liquid waste in its maximum configuration, based on 16 operating hours.

The modular system offers nominal treatment flow rates from 13.2 to 52.8 gpm (3,000 to 12,000 L/h).

Is ULTIMATE PLUS a batch or continuous EDS system?

ULTIMATE PLUS is a continuous-flow Effluent Decontamination System.

It treats flowing biological liquid waste through controlled heating and thermal holding sections rather than successive batch cycles.

How does the modular design of ULTIMATE PLUS work?

ULTIMATE PLUS consists of a main treatment skid rated at 13.2 gpm (3,000 L/h) and up to three EXT3000 extension modules.

Each additional module provides another 13.2 gpm (3,000 L/h) of nominal capacity, allowing ACTINI to configure systems with total flow rates of 3,000, 6,000, 9,000, or 12,000 L/h.

Can ULTIMATE PLUS capacity increase after installation?

The modular architecture supports several capacity configurations.

ACTINI can evaluate future capacity additions, but expanding an installed system requires a technical assessment of available space, steam supply, electrical utilities, hydraulic connections, automation, and treatment requirements.

Does ULTIMATE PLUS offer redundant pumping?

Yes. ACTINI offers optional redundant pumping configurations for projects requiring additional operational flexibility.

Our engineering team evaluates the appropriate arrangement according to the process and availability requirements.

What is the difference between ULTIMATE and ULTIMATE PLUS?

Both systems use steam-heated continuous thermal treatment with integrated energy recovery.

ULTIMATE ULT-1000 provides a compact treatment solution with a maximum capacity of 4,200 gal/day (16,000 L/day).

ULTIMATE PLUS uses a modular architecture for higher treatment capacities, reaching 50,700 gal/day (192,000 L/day) with three extension modules.

Does ULTIMATE PLUS require steam or chilled water?

ULTIMATE PLUS uses steam for thermal treatment.

Its integrated heat recovery system eliminates the need for chilled water. ACTINI evaluates steam consumption and the required utility connections according to the selected capacity.

What treatment temperatures does ULTIMATE PLUS use?

ULTIMATE PLUS supports treatment temperatures from 176°F to 275°F (80°C to 135°C), with a standard 1-minute holding time and an optional 2-minute configuration.

ACTINI defines the operating conditions according to the biological inactivation objectives, system configuration, and process requirements.

Can ULTIMATE PLUS treat effluents containing solids or viscous materials?

ULTIMATE PLUS is designed for aqueous, water-like biological liquid waste.

For effluents containing significant solids, particles, or viscous phases, ACTINI can evaluate alternative technologies such as CYCLOBATCH / BDS.

Tecnical schema

Request a quote