Home > Products > Effluent decontamination systems (EDS) > Laboratory effluent decontamination systems > KUBE – Laboratory effluent decontamination system

KUBE - Laboratory effluent decontamination system

Compact, fully automated thermal biowaste treatment at the point of use.

KUBE is a compact, electrically heated Effluent Decontamination System (EDS) designed for the thermal treatment of biologically contaminated liquid waste in laboratories and research facilities.

With a treatment capacity of up to 26 gal/day (100 L/day), KUBE combines automated batch operation, controlled thermal treatment, and a space-saving design. It connects to laboratory liquid waste collection points, including biosafety cabinets and existing sinks, depending on the installation configuration.

Key specifications:

  • Capacity: Up to 26 gal/day (100 L/day)
  • Technology: Electric batch EDS
  • Treatment: 275°F (135°C) for 2 minutes, adjustable
  • Thermal lethality: F₀ ≥ 50
  • Collection tank: 6.6 gal (25 L)
KUBE - Actini USA

Why choose KUBE for laboratory biowaste treatment?

KUBE provides automated thermal decontamination in a compact system designed for laboratories with limited installation space.

Compact point-of-use design

KUBE integrates into laboratory workspaces and connects to existing liquid waste collection points, including biosafety cabinets and laboratory sinks.

Fully electric operation

KUBE uses electric heating and does not require an external steam supply. Its single-phase electrical connection simplifies utility integration.

Automated treatment cycles

KUBE controls and monitors thermal treatment cycles to support repeatable operation while reducing the need for manual intervention.

Controlled thermal treatment

KUBE uses defined temperature and holding-time conditions to deliver the required thermal treatment. Its standard program operates at 275°F (135°C) for 2 minutes, with adjustable settings.

Flexible laboratory integration

ACTINI offers an optional containment configuration for installations with additional containment requirements. Our engineering team evaluates the appropriate configuration based on each laboratory’s application.

KUBE technical specifications & benefits

Parameter

Specification

Benefits

Equipment KUBE Compact, dedicated solution for laboratory biowaste treatment.
Application Laboratory liquid biowaste decontamination Supports biological liquid waste management directly within laboratory facilities.
Technology Batch thermal treatment Provides controlled, repeatable treatment cycles.
Heating method Electric No external steam supply required.
Maximum daily capacity 26 gal/day (100 L/day) Suitable for laboratories generating small volumes of liquid biowaste.
Effluent characteristics Aqueous / water-like Optimized for water-based laboratory effluents.
Collection tank capacity 6.6 gal (25 L) Collects liquid waste before automated treatment.
Standard treatment cycle 275°F (135°C) for 2 minutes Delivers controlled thermal exposure for biological inactivation.
Treatment settings Adjustable Allows adaptation to specific treatment requirements.
F₀ ≥ 50 Provides a measurable thermal lethality parameter to support treatment verification.
Electrical supply 120 V / 60 Hz / single-phase Compatible with the specified US single-phase electrical supply.
Electrical power 1.1 kW / 10 A Low installed electrical power compared with larger industrial systems.
Standard dimensions (L × W × H) 24 × 32 × 32 in (600 × 800 × 820 mm) Compact footprint helps integration into space-constrained laboratories.
Dimensions with containment option 25 × 32 × 48 in (640 × 810 × 1,220 mm) Offers an alternative configuration for laboratory containment requirements.

Confirm installation requirements and available options during project engineering.

How does the KUBE effluent decontamination system work?

KUBE uses automated batch thermal treatment to process biological liquid waste.

1. Liquid Waste Collection

The system collects biologically contaminated liquid waste from connected laboratory equipment or collection points.

2. Automated Batch Treatment

KUBE transfers collected effluent into its thermal treatment process and applies controlled heating and holding-time conditions.

3. Treatment Monitoring

The system monitors treatment parameters to support consistent operation and verification of the thermal cycle.

4. Cooling and Discharge

Following treatment, the system cools the effluent before discharge through the designated outlet.

Treatment parameters and discharge requirements must match the facility’s specific application and operating conditions.

Tecnical schema

KUBE configuration and available options

Ajout - scalable - cuve

Containment configuration

ACTINI offers an optional containment configuration for laboratory installations requiring additional containment measures. Our engineering team evaluates its suitability based on each facility's biological risks and operating requirements.

supervision

Remote control

Available remote-control options provide additional operational flexibility, depending on the selected equipment configuration.

Checklist

Treatment cycle reporting

KUBE monitors treatment parameters to support consistent and repeatable operation. ACTINI can review specific reporting and traceability requirements during project engineering.

Technology

Connection to laboratory collection points

KUBE connects to suitable liquid waste collection points, including laboratory sinks and biosafety cabinets. ACTINI evaluates the connections, installation layout, and operating requirements for each project.

Typical KUBE applications

KUBE is designed for laboratories and small-scale biotechnology facilities generating limited quantities of aqueous biological liquid waste.

Potential applications include:

  • Research and development laboratories
  • Biotechnology laboratories
  • Pharmaceutical research facilities
  • Laboratory biosafety cabinets and liquid waste collection points
  • Facilities upgrading their laboratory liquid waste management systems

ACTINI USA evaluates effluent composition, biological treatment requirements, containment needs, and installation constraints to confirm equipment suitability.

KUBE ACTINI GROUP
Tecnical schema

Need a compact laboratory EDS?

Whether you’re equipping a new laboratory or upgrading an existing liquid waste treatment process, ACTINI USA helps you evaluate KUBE’s suitability for your application.

Our engineering team supports your project from equipment selection and integration planning through commissioning and qualification support.

Frequently asked questions about KUBE (FAQ)

What is the maximum treatment capacity of KUBE?

KUBE treats up to 26 gal/day (100 L/day) of biological liquid waste. Actual capacity depends on the operating conditions and selected treatment parameters.

Does KUBE require a steam supply?

No. KUBE uses electric heating with a 120 V, 60 Hz, single-phase power supply. It does not require an external steam connection.

Can KUBE connect to a laboratory sink or biosafety cabinet?

Yes. KUBE supports integration with existing laboratory sinks and biosafety cabinets. ACTINI evaluates the required connections and installation configuration for each project.

What treatment temperature does KUBE use?

KUBE’s standard treatment program operates at 275°F (135°C) with a 2-minute holding time. ACTINI can adjust treatment settings according to the selected configuration and validated process requirements.

Can KUBE be used in high-containment laboratories?

ACTINI offers an optional containment configuration for applications with additional containment requirements. Our engineering team evaluates biological risks, facility specifications, and treatment objectives before confirming the appropriate configuration.

Tecnical schema