Home > Products > Effluent decontamination systems (EDS) > Laboratory effluent decontamination systems > DIRECTSTEAM – Laboratory effluent decontamination system

DIRECTSTEAM - Laboratory effluent decontamination system

Steam-heated thermal biowaste treatment for challenging liquid effluents containing particles and viscous materials.

DIRECTSTEAM is an automated, steam-heated Effluent Decontamination System (EDS) designed for the thermal treatment of biologically contaminated liquid waste containing suspended solids, particles, or viscous phases. With a treatment capacity of up to 260 gal/day (1,000 L/day), DIRECTSTEAM combines direct steam injection, continuous recirculation, and controlled batch treatment to handle liquid waste streams that may not be suitable for conventional electric laboratory EDS systems.

Its integrated recirculation system promotes mixing and heat distribution during treatment, while the automated control system monitors the thermal process.

Key specifications:

  • Capacity: Up to 260 gal/day (1,000 L/day)
  • Technology: Steam-heated batch EDS
  • Treatment: 275°F (135°C) for 2 minutes or 250°F (121°C) for 20 minutes
  • Thermal lethality: Adjustable F₀ from 20 to 50
  • Collection tank: 260 gal (1,000 L)
  • Effluent compatibility: Particles and viscous liquid waste
  • Heating: Direct steam injection with continuous recirculation
laboratory decontamination system

Why choose DIRECTSTEAM for laboratory biowaste treatment?

DIRECTSTEAM provides automated thermal decontamination for laboratories and biotechnology facilities that generate challenging biological liquid waste.

Designed for challenging effluents

DIRECTSTEAM handles liquid waste containing particles, suspended solids, or viscous phases. Its treatment technology addresses applications that require more than conventional water-like effluent processing.

Direct steam injection

DIRECTSTEAM injects steam directly into the treatment process to heat the biological liquid waste. This heating approach supports controlled thermal treatment without relying on electric heating of the effluent.

Integrated heat exchanger

DIRECTSTEAM incorporates a heat exchanger to manage the treated effluent’s outlet temperature and support integration with the facility’s discharge requirements.

Continuous recirculation and mixing

An integrated recirculation pump circulates the effluent during treatment. Combined with tangential steam injection, this configuration promotes mixing and heat distribution throughout the process.

Automated thermal treatment

DIRECTSTEAM controls treatment temperature, holding time, and process monitoring to support repeatable batch operation. The system offers different thermal programs to accommodate application-specific treatment requirements.

DIRECTSTEAM technical specifications & benefits

Parameter

Specification

Benefits

Equipment DIRECTSTEAM Dedicated thermal treatment solution for challenging biological liquid waste.
Application Laboratory liquid biowaste decontamination Supports treatment of biological effluents from research and biotechnology processes.
Technology Batch thermal treatment Provides controlled treatment cycles for variable waste generation.
Heating method Direct steam injection Delivers thermal energy directly to the liquid waste.
Maximum daily capacity 260 gal/day (1,000 L/day) Provides greater treatment capacity than smaller laboratory EDS models.
Effluent characteristics Particles / viscous liquid waste Accommodates challenging effluent compositions, subject to application review.
Collection tank capacity 260 gal (1,000 L) Collects biological liquid waste before thermal treatment.
Treatment vessel capacity 2.6 gal (10 L) Supports controlled batch thermal treatment.
Standard treatment programs 275°F (135°C) for 2 min or 250°F (121°C) for 20 min Offers treatment programs for different application requirements.
F₀ Adjustable 20 - 50 Allows configuration of the thermal lethality target.
Steam supply 65 psig (4.5 barg) Provides the required steam pressure for direct heating.
Steam consumption 66 lb/hr (30 kg/h) Provides a basis for steam utility sizing.
Electrical supply 120 V / 60 Hz / single-phase Supplies the electrical control and auxiliary equipment.
Electrical power 1.8 kW Defines the electrical utility requirement.
Effluent recirculation Integrated recirculation pump Promotes mixing and heat distribution during treatment.
Heat exchanger Integrated Supports management of the effluent discharge temperature.
Standard dimensions (L × W × H) 54 × 104 × 82 in (1,360 × 2,650 × 2,070 mm) Provides defined dimensions for equipment layout and installation planning.
Solids handling option Optional in-line crusher Provides an additional option for selected particle-containing or fibrous effluents.

Maximum treatment capacity depends on the selected thermal program, effluent characteristics, steam availability, and operating conditions. Confirm installation requirements and options during project engineering.

How does the DIRECTSTEAM effluent decontamination system work?

DIRECTSTEAM uses automated batch thermal treatment with direct steam injection and continuous recirculation to process biologically contaminated liquid waste.

1. Liquid waste collection

DIRECTSTEAM collects biological liquid waste in its dedicated collection tank before treatment. The system accommodates suitable liquid effluents containing particles or viscous phases.

2. Direct steam heating and recirculation

The system transfers effluent into its treatment process and injects steam directly into the liquid waste.

An integrated recirculation pump continuously circulates the effluent during treatment, promoting mixing and heat distribution.

3. Controlled thermal treatment

DIRECTSTEAM maintains the selected treatment temperature and holding time while monitoring operating parameters.

The system supports treatment programs at 275°F (135°C) for 2 minutes or 250°F (121°C) for 20 minutes, according to the selected configuration.

4. Cooling and discharge

Following the thermal treatment cycle, DIRECTSTEAM uses its integrated heat exchanger to manage the outlet temperature before discharging the treated effluent.

ACTINI evaluates waste composition, steam requirements, treatment performance, and discharge conditions to define the appropriate operating configuration.

Tecnical schema

DIRECTSTEAM configuration and available options

Programme de traitement

Direct Steam injection and recirculation

DIRECTSTEAM combines tangential steam injection with continuous recirculation to promote mixing and controlled heating of challenging effluents.

Conception fabrication icone

Optional in-line crusher

ACTINI offers an optional in-line crusher for selected effluents containing solids or fibrous materials. Our engineering team evaluates particle characteristics and process requirements to determine whether the option is appropriate.

température icone

Adjustable thermal treatment programs

DIRECTSTEAM supports different treatment temperatures and holding times, with configurable thermal lethality requirements.

Energie electricité

Integrated heat exchanger

The integrated heat exchanger supports control of the treated liquid's discharge temperature.

supervision

Automated cleaning

DIRECTSTEAM includes an automated cleaning function to support equipment operation and maintenance. ACTINI reviews cleaning requirements and compatibility with the effluent during project engineering.

Typical DIRECTSTEAM applications

DIRECTSTEAM is designed for research, biotechnology, and laboratory-scale facilities that generate biologically contaminated liquid waste containing particles or viscous materials.

Potential applications include:

  • Biotechnology research and development laboratories
  • Pharmaceutical and biopharmaceutical research facilities
  • Laboratories generating biological waste with suspended solids
  • Pilot-scale fermentation and biotechnology processes
  • Facilities requiring dedicated treatment of viscous biological liquid waste

ACTINI USA evaluates effluent composition, particle characteristics, viscosity, biological treatment requirements, and installation constraints to confirm equipment suitability.

laboratory decontamination system
Tecnical schema

Need an EDS for challenging laboratory effluents?

Whether you’re designing a biotechnology laboratory, upgrading a pilot-scale facility, or looking for a treatment solution for biological liquid waste containing particles or viscous materials, ACTINI USA helps you evaluate DIRECTSTEAM’s suitability for your process.

Our engineering team supports equipment selection, effluent assessment, utility integration, commissioning, and qualification activities according to your project requirements.

Frequently asked questions about DIRECTSTEAM (FAQ)

Can DIRECTSTEAM treat biological liquid waste containing solids?

Yes. DIRECTSTEAM uses direct steam injection and continuous recirculation to treat suitable biological liquid waste containing particles or suspended solids.

ACTINI evaluates particle size, concentration, and effluent characteristics to determine the appropriate configuration, including the potential use of an optional in-line crusher.

What is the maximum treatment capacity of DIRECTSTEAM?

DIRECTSTEAM treats up to 260 gal/day (1,000 L/day) of biological liquid waste. Actual capacity depends on the selected treatment program, effluent characteristics, available utilities, and operating conditions.

Does DIRECTSTEAM require a steam supply?

Yes. DIRECTSTEAM uses direct steam injection for thermal treatment. The brochure specifies a steam supply of 65 psig (4.5 barg) and a steam consumption of 66 lb/hr (30 kg/h).

The system also requires a 120 V, 60 Hz, single-phase electrical supply for its auxiliary equipment.

Is DIRECTSTEAM a batch or continuous EDS system?

DIRECTSTEAM is a batch EDS system. It processes biological liquid waste through controlled thermal treatment cycles.

The system continuously recirculates the effluent during treatment, but this internal recirculation does not make DIRECTSTEAM a continuous-flow EDS.

What treatment temperatures does DIRECTSTEAM use?

DIRECTSTEAM supports treatment programs at 275°F (135°C) for 2 minutes or 250°F (121°C) for 20 minutes.

ACTINI defines the appropriate operating parameters according to the biological treatment objectives and selected equipment configuration.

What is the difference between DIRECTSTEAM and MICRO10?

Both systems provide automated batch thermal decontamination, but they address different waste characteristics.

MICRO10 uses electric heating and is designed for aqueous, water-like effluents, with a capacity of up to 80 gal/day (300 L/day).

DIRECTSTEAM uses direct steam injection and recirculation to treat suitable effluents containing particles or viscous phases, with a capacity of up to 260 gal/day (1,000 L/day).

Tecnical schema

Request a quote